On Tuesday July 31, 2012, India’s interconnected power grids failed, leaving half the population without electricity.
Cascading failures occur in systems of interconnected parts. They usually begin when one part of the system fails. Nearby system parts must then compensate for the failed component, which can overload that part to trigger a vicious cycle as successive parts fail.
When Federal Energy Regulatory Commission (FERC) chairman Jon Wellinghoff was asked if power problems in the Northeast could spread all the way to California, he told ABC News, “It’s very, very unlikely that ultimately would happen.” Part of why the risk is low, the ABC story conveyed, is due to our nation’s grid being divided in the middle.
Unfortunately, this division still leaves hundreds of millions at risk for cascading failures, and increased investment in transmission is in NOT the answer.
A comprehensive, three-year DoD and Federal Emergency Management Agency study — Brittle Power: Energy Strategy for National Security — concluded that relying on massive, complex, and interconnected infrastructures that need to transmit and deliver power from centralized generation create unavoidable (and costly) vulnerabilities.
Cascading failures in “brittle” interconnected electrical systems can be induced by severe weather, human error, sabotage, or even the interference of small animals. Conversely, resilient infrastructure systems are less likely to collapse in the face of natural or manmade disruptions and will limit damage when disruptions occur.
A 2007 US Department of Energy (DOE) study, The Potential Benefits of Distributed Generation and Rate-Related Issues that May Impede Their Expansion, provides compelling evidence of how a distributed network of smaller sources was able to adjust to problems without causing major consequences. A decentralized system also reduced the magnitude and duration of failures.
The DoD study on “brittle power” further concluded that centralized energy facilities create tempting targets for terrorists because the terrorists would need to attack only a few, poorly guarded facilities to cause large, catastrophic power outages. In a complementary study, Energy Security in a Dangerous World, the International Energy Agency reaches the same conclusion.
Examples from nearly every area of critical infrastructure defined by the Department of Homeland Security verify distributed generation (DG) to be a viable means for reducing vulnerability to terrorism and improving the resilience of electrical infrastructure. This is based on actual cases where DG continued to provide power to critical facilities during times of large-scale power disruptions and outages, and is documented in the 2007 DOE study.
Richard Clarke, a former national security adviser and ABC News consultant also conveyed, during the ABC Nightly News coverage of Black Tuesday, that today’s biggest grid threat is cyber-attack. “The U.S. power grid is extremely vulnerable to cyber-attack,” Clarke said. “The government is aware of that. Recently the government held a White House level cyber exercise in which the scenario was a cyber-terrorist attack that took down the power grid.”
A July 17, 2012 webinar, New Approaches to Grid Security, featured three of the electric industry’s most knowledgeable and influential leaders in grid reliability -- Terry Jarrett, MPSC regulator and chair of NARUC committee on critical infrastructure, Terry Boston, president and CEO of PJM Interconnections, and Gerry Cauley, president and CEO of North American Electric Reliability Corp.
Each of these experts stressed the importance of resilience – the ability of the electrical infrastructure to quickly respond to cyber, terrorist and weather induced attack. Mr. Cauley also conveyed how the interconnected grid throughout the US and Canada created challenges to protecting the grid from cyber-attack due to issues related to information sharing and analysis.
Expert testimony from Dr. Benjamin Sovacool regarding a 500 kV transmission line in Virginia demonstrated how long-distance transmission reduces the stability of the electric grid. Dr. Sovacool concluded, “The proposed project should be rejected on grounds that it fails to provide substantial reliability and security as defined by (the utility) Dominion itself. Instead, the proposed line increases the vulnerability of Virginia and the National Capital Area to critical national security threats.”
Dominion -- one of the nation's largest producers and transporters of energy, which serves electrical needs for customers in Virginia, West Virginia, Ohio and North Carolina -- received permission to construct this project connecting Meadow Brook to Loudoun. The $243 million, 65-mile long overhead transmission line was placed in service in mid-2011. On June 29 2012, more than a million customers in DC, Virginia and Maryland suffered mass power outoutages due to “derecho” storms. The area’s electrical grid was slow to recover.
The August 14, 2003 rolling blackout of the East Coast was, at the time, the second most wide-spread blackout in history, affecting an estimated 45 million people in eight U.S. states and 10 million people n Ontario. In this disaster, a power surge affected the transmission grid, resulting in a cascading failure. The tools in place to analyze the “what ifs” didn’t do their job and the appropriate people didn’t understand the issue was theirs until their own lights went off. By then, an uncontrollable cascading failure was under way and it was too late for human intervention to save the grid.
In 2005, Congress put in place financial incentives to improve existing transmission to prevent future blackouts. Since then, most of the funding has been diverted to new transmission and, in 2011, the US experienced another significant black-out.
In reviewing the cause of the September 28, 2011 blackout, which affected up to 5 million people in California, Arizona and Mexico, NERC and FERC found “common underlying causes” to the 2003 East Coast black-out. The power loss should have been limited to the Yuma, Arizona, area but, according to the power company, Arizona Public Service, “…an employee was just switching out a piece of equipment that was problematic."
This clearly indicates that transmission incentives have not produced a corresponding increase in reliability that would prevent future blackouts, as Congress intended. Despite this, building more and more interconnected transmission is rampant. $170 billion in new transmission is planned nationally between now and 2020. In Wisconsin alone eight new high voltage lines planned that will greatly increase inter-connection from Maine to the Dakotas.
CapX2020, a controversial and contested high voltage transmission line, is planned to cross the Mississippi River at Alma, Wisconsin. Despite testimony of inherent grid instability, the Wisconsin Public Service Commission (PSC) approved CapX2020 on May 30, 2012.
The next interconnected segment of this line, known as Badger Coulee, would connect to Madison.
This type of transmission expansion is planned all over the country, making further interconnection of the nation’s grid imminent and immense.
The utilities behind CapX2020 and the Wisconsin PSC contend the line is needed for “regional reliability.” Those leading the court challenge against the line believe this is a manipulation of the term as it is economically driven and defined by the ability to more reliably move electricity around to sell to other markets.
It is time to for utilities to embrace another approach and to more fully acknowledge inherent issues in monitoring and controlling an interconnected grid. Dr. Sovacool warned in his 2007 testimony, “Long distance transmission is not reliable. Given the complexity of the modern electrical system, and what we know about the role reactive power has played in recent outages, relying on longer transmission lines to wheel greater amounts of real power is perhaps the worst strategy for ensuring system reliability. Large and long transmission lines lose reactive power the larger and longer they become, requiring the system to compensate in ways that increase the likelihood of systems collapse.”
Dr. Sovacool also shared how catastrophic failures are most often the result of human error, inadequate diagnostics, and/or voltage instability due to insufficient reactive power — the power that keeps voltage and current in phase.
In electric transmission, if a fault occurs and takes a line out, the change in current flow is compensated by other transmission lines. If they lack the capacity to carry the excess current, overload protection in those lines will also trip, causing a cascading failure as the excess current is switched onto neighboring circuits running at or near their capacity.
The role of a system operator is to monitor power supply and demand to keep them balanced and within safe operational limits. If a system failure occurs, operators must get power from generators or other regions or reduce their load to bring the system into balance and, hopefully, avoid a cascading system failure. Computer systems, with backups and alarms, are used to monitor the system. If the computer systems fail, system operators monitor the grid manually. Local operators are coordinated by regional centers, but the operating principle is the same for the larger network. Applying this and lessons learned in the 2003 and 2011 US blackouts and to Black Tuesday in India -- the largest in human history – is highly relevant and insightful.
Human and equipment error will continue to happen, and interconnected systems are vulnerable to cascading failures. It simply is what it is. Fortunately many of India’s major corporations and industrial groups were spared much of the blackout disruption because they generate their own power.
Perhaps, in the US, we are not encouraging investment in the right kind of improvements to enable similar avoidance of distress. Perhaps it is time to invest in an efficient, diverse, dispersed electricity system, where major failures—whether by accident or malice—become improbable by design rather than inevitable by design. The number of citizens, municipalities, states and associations asking that viable, cost-effective and sustainable alternatives to high voltage transmission be evaluated is growing. Unfortunately, so is the number of transmission lines being built and planned.
Due to this pressure, FERC has agreed to evaluate whether its own incentives are leading to an over-application for transmission and subsequent profits. Citizens are also suggesting that a conflict-of interest may exist in the planning groups of the Midwest regional grid operator (MISO) by having for-profit transmission builders at the helm of their Planning Advisory Committee and Planning Subcommittee. The dauntingly high operating-margins provide further insight into why some feel it is
greed, not need, that is driving this push for transmission.
In December 2011, Financial News Network reported that ITC Holdings, the largest for-profit transmission only company, has the highest operating margins in the electric industry (51.7%). ATC, which wants to build the high voltage line connecting La Crosse to Madison, has an even higher margin of 54.9% when dividing 2010 operating income by revenue. In Wisconsin, a legal battle has ensued between Xcel and ATC regarding ownership of the Badger Coulee line and the subsequent profits.
The public also is not accepting ATC’s claim that looking into non-transmission alternatives is “beyond the scope of the (transmission) project.” Instead, ratepayers are asking the Wisconsin PSC for cost/benefit analysis of feasible alternatives, including how they impact grid reliability and the sustainability of our natural resources. They are educated on job creation and energy savings benefits of energy efficiency over transmission, as well as the benefits of home grown energy and a decentralized grid.
The commitment and tenacity to address these issues is evidenced by groups including Citizens Energy Task Force (CETF)/No CapX2020, Piedmont Environmental Council and Stop PATH WV, which are willing to lead the charge all the way to the courts.
Incidents such as the black-out in India, terrorist attacks on September 11, 2001, the Northeast Blackout of August 2003 and Hurricane Katrina are wake up calls. They remind us how dependent we are on electricity and how fragile a brittle grid can be.
We’re at a fork in the road.
Before we invest hundreds of billions of dollars in interconnected transmission, we must heed the experts and activists who are working to replace the outdated paradigms of infrastructure protection and infrastructure centralization with infrastructure resilience.
The time to change our course is now, before what happened in India threatens half the American public.